The Fluke 572-2 High-Temperature Infrared Thermometer is the one product you can use in high-temperature industrial environments all around the world. Whether you work in power utility, metal refining and smelting, glass, cement or petrochemical environments, the 572-2 allows you to carry the most trusted name in test tools anywhere you need accurate, high-temperature and high distance-to-spot measurements.
With a straight-forward user interface and soft-key menus, the Fluke 572-2 makes even complex measurements easy. Quickly navigate and adjust emissivity, start data logging, or turn on and off alarms, with just a few pushes of a button.
Features:
Measures -30 C to 900 C (-22 F to 1652 F) Has 60:1 distance to spot ratio with dual laser sighting for fast, accurate targeting Multi-language interface (user select) Current Temperature plus MAX, MIN, DIF, AVG temperature displays Compatible with standard mini-connector K-type thermocouples, including ones you already own and have installed Adjustable emissivity and predefined emissivity table Infrared and thermocouple temperature on back-lit display Last reading Hold (20 seconds) High and low temperature alarm Data storage and review (99 data sets) Tripod mount 12 or 24 hour clock USB 2.0 computer interface cable FlukeView Forms documenting software
Warranty:
2 Years Manufacturer Warranty + Additional 1 Year Instrument Choice Warranty
Specifications
Infrared Measurements |
Infrared temperature range |
-30 C to 900 C (-22 F to 1652 F) |
IR accuracy (calibration geometry
with ambient temperature 23 C ? 2 C)
|
>= 0C: +- 1C or +- 1 % of the reading, whichever is greater >= -10C to <0 C: +-2C <-10C: +-3 C
>= 32F: +- 2F or +- 1% of the reading, whichever is greater >= 14 F to <32 F: +-4 F < 14 F: +-6 F |
IR repeatability |
+- 0.5 % of reading or +-0.5 C (+-1 F), whichever is greater |
Display resolution |
0.1 C / 0.1 F |
Distance: Spot |
60:1 (calculated at 90 % energy) |
Minimum spot size |
19 mm |
Laser sighting |
Offset dual laser, output <1 mW |
Spectral response |
8 um to 14 um |
Response time (95 %) |
<500 ms |
Emissivity |
Digitally adjustable from 0.10 to 1.00 by 0.01 or via built-in table of common materials |
Contact Measurements |
K-type thermocouple input accuracy
(with ambient temperature 23 ?C ? 2 ?C)
|
<- 40 C: +-(1 C + 0.2 /1 C) |
>= -40 C: +-1 % or 1 C, whichever is greater |
<- 40 F: +-(2 F + 0.2 /1 F) |
>= -40 F: +-1 % or 2 F, whichever is greater |
K-type thermocouple |
0.1 C/0.1 F |
K-type thermocouple repeatability |
+- 0.5 % of reading or +- 0.5 C (+- 1 F), whichever is greater |
Measurement Options |
Hi/Low alarms |
Audible and two-color visual |
Min/Max/Avg/Dif |
Yes |
Switchable celsius and fahrenheit |
Yes |
Backlight |
Two levels, normal and extra bright for darker environments |
Probe input |
K-type thermocouple simultaneous display of probe and IR temperature |
Trigger lock |
Yes |
Data storage |
99 points |
Display |
Dot matrix 98 x 96 pixels with function menus |
Communication |
USB 2.0 |
K-Type Thermocouple Specifications |
Measurement range (bead probe) |
-40 C to 260 C (-40 F to 500 F) |
Accuracy |
+- 1.1 C (+- 2.0 F) from 0 C to 260 C (32 F to 500 F). Typically within 1.1 C (2.0 F) from -40 C to 0 C (-40 F to 32 F) |
Cable length |
1 m (40 in) K-type thermocouple cable with standard miniature thermocouple connector and bead termination |
General Specifications |
Safety and compliance |
IEC 60825-1 FDA Laser Class II IEC 61326-1 CE Complaint CMC # 01120009 |
Operating temperature |
0 C to 50 C (32 F to 122 F) |
Storage temperature |
-20 C to 60 C (-4 F to 140 F) |
Relative humidity |
10 % to 90 % RH non-condensing up to 30 C (86 F) |
Operating altitude |
2000 meters above mean sea level |
Weight |
0.322 kg (0.7099 lb) |
Power |
2 AA batteries |
Battery life |
8 hours with laser and backlight on; 100 hours with laser and backlight off, at 100 % duty cycle (thermometer continuously on) |
|
|
|
Reviews
There are no reviews yet.