FLASH SALE: EVERYTHING HALF PRICE! LIMITED TIME ONLY!
CAT-MT Anemometer Kit with Airmar Weather Station - IC-ORB-X1-120WXH Sale!

CAT-MT Anemometer Kit with Airmar Weather Station – IC-ORB-X1-120WXH

  • $2,461.99
  • $98.00

ORB-X1 (GSM) The ORB-X1-G with GPS has sensors to allow the measurement of voltage, current, position, speed, tilt, temperature, pressure, frequency, and serial data. Data measured by the ORB-X1-G is transmitted via GSM and can be delivered to the Senquip

  • 100% Happiness Backed or Your Money Back
  • Free Delivery on 30+ Orders
  • 60-Day Hassle-Free Returns

SKU: ZT75362000593

Category:

ORB-X1 (GSM)

The ORB-X1-G with GPS has sensors to allow the measurement of voltage, current, position, speed, tilt, temperature, pressure, frequency, and serial data. Data measured by the ORB-X1-G is transmitted via GSM and can be delivered to the Senquip Portal or to your own server.

Features:

– Multi-sensors: Measure voltage, current, position, speed, tilt, temperature, pressure, frequency, serial data and more.
– WIFI and GSM: CAT-M1 GSM ensures best possible coverage and least possible power. WiFi connectivity allows for connection to local networks.
– Multiple protocols: SMS, UDP, MQTT, TCP and more.
– Secure data: Embedded certificates and secure communications.
– Notifications: Configurable levels for each notification
– Adaptable: Users write their own scripts.
– Versatile mounting: Ships with pole and wall mount options.
– Built tough: Designed for use in harsh industrial environments.
– Simple setup: Use any phone, tablet, or laptop with the integrated web server.
– Cloud services: Access to the Senquip Portal for viewing of data, storage, remote setup and firmware upgrades
– Integrated light sensor – Used to activate the ORB setup functions when the lid is opened and to detect tamper attempts. The light sensor is sampled on a regular basis and does not have an associated measurement interval.

Internal sensor specifications

Accelerometer:

– G-force range: +/- 16G
– Resolution: 1mG
– Sensitivity change vs temperature: 0.1% per C
– Typical zero-g level offset accuracy: +/- 40mG
– Tilt resolution: 0.1 deg
– Tilt accuracy (0-45 deg): 1.0 deg
– Tilt accuracy (45-90 deg): 2.0 deg

Pressure Sensor:

– Pressure range: 300 – 1100 hPa
– Temperature range: -40 to 85 C
– Absolute accuracy (0 to 65 deg C): +/-1 hPa
– Relative accuracy (25 to 40 deg C): +/-0.12 hPa, equivalent to +-1 m altitude
– Absolute maximum pressure: 20,000 hPa

Temperature sensor:

– Measurement range: -40 to 85 C
– Resolution: 0.01 deg C
– Absolute accuracy (25 C): +/-0.5 deg C
– Absolute accuracy (0 – 65 C): +/-1 deg C

GPS:

– Time to first fix from power up: Typically 60 seconds
– Position update rate: Maximum 1Hz
– Horizontal position accuracy: Typically +-5m
– Vertical position accuracy: Typically +-20m
– Horizontal speed accuracy: 1km/h

120WXH WeatherStation

The WXH models have been carefully designed with a sophisticated heat-ing system for operation in ice-prone areas, both onshore and offshore. Its compact size, robust construction, and no moving parts provide many years of reliable service despite the harsh weather conditions associated with many land and marine applications. The WXH models are designed, developed and manufactured to meet a growing need for real-time, site specific, weather information.

Features:

– Measures apparent wind speed and angle, barometric pressure, air temperature and wind chill temperature.
– Appropriate for stationary mounting and operation
– Made with an internal heating system to protect against ice and freezing temperatures
– Built with no moving parts to ensure reliable operation
– Includes NMEA 0183 (RS422) output

Specifications

Wind speed:

– Range: 0-40 m/s
– Accuracy: 5% at 10 m/s (at 4 angles)
– Resolution: 0.1 m/s
– Units: m/s
– Calculations: User configurable damping

Wind direction:

– Range: 0 to 359.9 degrees
– Accuracy: +/- 3 degrees at 10 m/s
– Resolution: 0.1
– Calculation: User configurable damping

Air temperature:

– Range: -40 to 80 C
– Accuracy: +/- 1.1 C at 20 C
– Resolution: 0.1
– Units: C

Barometric pressure:

– Range: 300 to 1100 hPa
– Accuracy: +/- 0.5 hPa at 25 C (or better)
– Resolution: 0.1 hPa

Other specifications:

– Operating temperature range: -25 to 55 C
– Heater operating temperature range: -40 to 55 C
– Heater cycles on when sensor reaches 1 C
– Supply Voltage: 12 VDC to 24 VDC
– Supply Current (at 24 VDC): <28 mA (<0.7 W), LEN 2
– Heater Supply Current (at 24 VDC):<2.5 A (<60 W)
– Certifications and Standards: CE, IPX6 (Relative Humidity/IPX4), RoHS, IEC61000-4-2, IEC60945, IEC60950_1C, IEC60950_22A, EN55022, EN55024, EN15014982

Cost:

$25

Free Shipping:

We offer free shipping on orders over $30. Please check the free - shipping eligibility at checkout.

Delivery Time:

It usually takes [3-5] business days for standard shipping. Please note that this is an estimated time frame and may be affected by local holidays, and unforeseen circumstances.

Reviews

There are no reviews yet.

Be the first to review “CAT-MT Anemometer Kit with Airmar Weather Station – IC-ORB-X1-120WXH”

Your email address will not be published. Required fields are marked *